{"id":9645,"date":"2016-08-08T01:25:08","date_gmt":"2016-08-08T01:25:08","guid":{"rendered":"http:\/\/www.kurzweilai.net\/?p=285894"},"modified":"2016-08-11T05:13:16","modified_gmt":"2016-08-11T05:13:16","slug":"ultrasonic-wireless-neural-dust-sensors-monitor-nerves-muscles-in-real-time","status":"publish","type":"post","link":"https:\/\/hoo.central12.com\/fugic\/2016\/08\/08\/ultrasonic-wireless-neural-dust-sensors-monitor-nerves-muscles-in-real-time\/","title":{"rendered":"Ultrasonic wireless &lsquo;neural dust&rsquo; sensors monitor nerves, muscles in real time"},"content":{"rendered":"<div id=\"attachment_285897\" class=\"wp-caption aligncenter\" style=\"width: 569px;  border: 1px solid #dddddd; background-color: #f3f3f3; padding-top: 4px; margin: 10px; text-align:center; display: block; margin-right: auto; margin-left: auto;\"><a href=\"http:\/\/www.kurzweilai.net\/ultrasonic-wireless-neural-dust-sensors-monitor-nerves-muscles-in-real-time\/sensor-mote-piezoelectric-crystal\" rel=\"attachment wp-att-285897\"><img class=\" wp-image-285897\" title=\"sensor mote piezoelectric crystal\" src=\"http:\/\/www.kurzweilai.net\/images\/sensor-mote-piezoelectric-crystal.jpg\" alt=\"\" width=\"559\" height=\"372\" \/><\/a><p style=' padding: 0 4px 5px; margin: 0;'  class=\"wp-caption-text\">Prototype\u00a0wireless battery-less &#8220;neural dust&#8221; mote (3 x 1 x 1 millimeters) with electrodes attached to a nerve fiber in a rat. The mote contains a piezoelectric crystal (silver cube) that converts ultrasonic signals to electrical current, powering a simple electronic circuit containing a transistor (black square) that responds to the voltage generated by a nerve firing and triggers the piezoelectric crystal to create ultrasonic backscatter, which indicates detection of a neural signal. (photo credit: Ryan Neely\/UC Berkeley)<\/p><\/div>\n<p>University of California, Berkeley engineers have designed and built millimeter-scale device wireless, batteryless &#8220;neural dust&#8221; sensors and implanted them in muscles and peripheral nerves of rats to make <em>in\u00a0vivo<\/em> electrophysiological recordings.<\/p>\n<p>The new technology opens the door to \u201c<a href=\"https:\/\/en.wikipedia.org\/wiki\/Electroceuticals\" >electroceuticals<\/a>\u201d &#8212; bioelectronic methods to monitor and record wireless <a href=\"https:\/\/en.wikipedia.org\/wiki\/Electromyography\" >electromyogram<\/a> (EMG) signals from muscle membranes and <a href=\"https:\/\/en.wikipedia.org\/wiki\/Electroneurogram\" >electroneurogram<\/a> (ENG) signals from local neuron electrical activity, and to stimulate the immune system, reduce inflammation, and treat disorders such as epilepsy.<\/p>\n<p>The technology could also improve neural control of prosthetics (allowing a paraplegic to control a computer or a robotic arm, for example) by stimulating nerves and muscles directly, instead of requiring implanted wires.<\/p>\n<p>The neural-dust sensors use ultrasound technology to both power the sensors and read out measurements. Ultrasound is already well-developed for hospital use and can penetrate nearly anywhere in the body, unlike radio waves.<\/p>\n<p>The researchers reported their findings August 3 in an <a href=\"http:\/\/www.cell.com\/neuron\/abstract\/S0896-6273(16)30344-0\" >open-access paper<\/a> in the journal\u00a0<em>Neuron<\/em>.<\/p>\n<p><strong>How a neural dust &#8220;mote&#8221; sensor monitors neural and muscle signals<br \/>\n<\/strong><\/p>\n<div id=\"attachment_285898\" class=\"wp-caption aligncenter\" style=\"width: 439px;  border: 1px solid #dddddd; background-color: #f3f3f3; padding-top: 4px; margin: 10px; text-align:center; display: block; margin-right: auto; margin-left: auto;\"><img class=\" wp-image-285898 noshadow \" title=\"biocompatible gel device\" src=\"http:\/\/www.kurzweilai.net\/images\/biocompatible-gel-device.jpg\" alt=\"\" width=\"429\" height=\"283\" \/><p style=' padding: 0 4px 5px; margin: 0;'  class=\"wp-caption-text\">Diagram showing the components of the neural-dust mote (sensor). The entire device is covered in a biocompatible gel. (credit: Dongjin Seo et al.\/Neuron)<\/p><\/div>\n<p>1. A team implants the neural dust mote. In the reported study, the mote was implanted in the rat sciatic nerve to do ENG recordings and in the gastrocnemius muscle to do EMG recordings. The tether-less connection also avoids potential infections and adverse biological responses due to micro-motion of the implant within the tissue.<\/p>\n<p>2. An external ultrasonic generator sends a ultrasound signal to a <a href=\"https:\/\/en.wikipedia.org\/wiki\/Piezoelectricity\" >piezoelectric<\/a> crystal, which converts the sound energy into an electrical voltage, used to power a transistor circuit &#8212; no battery required.<\/p>\n<p>3. When neurons or muscle fibers fire, they generate a tiny voltage (action potential) that the two electrodes pick up and send to the transistor.<\/p>\n<p>4. The transistor amplifies the signal and drives the\u00a0piezoelectric crystal to vibrate at an ultrasonic rate.<\/p>\n<p>5. That vibration interferes with the transmitted ultrasonic signal, causing a modified &#8220;backscatter&#8221; signal that communicates information about the voltage across the sensor\u2019s two electrodes.<\/p>\n<div id=\"attachment_286078\" class=\"wp-caption aligncenter\" style=\"width: 439px;  border: 1px solid #dddddd; background-color: #f3f3f3; padding-top: 4px; margin: 10px; text-align:center; display: block; margin-right: auto; margin-left: auto;\"><img class=\" wp-image-286078\" title=\"EMG recording\" src=\"http:\/\/www.kurzweilai.net\/images\/EMG-recording.png\" alt=\"\" width=\"429\" height=\"220\" \/><p style=' padding: 0 4px 5px; margin: 0;'  class=\"wp-caption-text\">In vivo experimental setup for a tether-less neural dust electromyography (EMG) recording from the gastrocnemius muscle in rats. The neural dust mote was placed on the exposed muscle surface, and the wound was closed with surgical suture. The ASIC chip switches between ultrasound transmit and receive modules.Triggered by the FPGA chip, the external transducer sends ultrasound (TX, green) to the mote. The backscatter received signal (RX, red) carries information about the EMG voltage that is decoded and recorded\/displayed on a computer. The dust mote was pinged every 100 microseconds with six 540-nanosecond ultrasound pulses. (credit: Dongjin Seo et al.\/Neuron)<\/p><\/div>\n<p>6. The backscatter ultrasound signal is decoded to extract EMG or ENG data.<\/p>\n<p>7. A computer displays and records the information.<\/p>\n<p><strong>Microscale motes: future research<br \/>\n<\/strong><\/p>\n<p>The experiments so far have involved the peripheral nervous system and muscles, using an external ultrasonic patch over the implanted site to acquire\u00a0 information from the motes for the desired diagnosis or therapy.<\/p>\n<p>But according to the researchers, neural dust motes can be implanted anywhere in the body, including the central nervous system and brain to control prosthetics. This would be an alternative to today\u2019s implantable electrodes (for Parkinson&#8217;s disease, for example), which require wires that pass through holes in the skull and degrade within one to two years.<\/p>\n<p>The researchers are now building motes from biocompatible thin films, which would potentially last in the body without degradation for a decade or more. Up to hundreds of wireless sensors could be sealed in, avoiding infection and unwanted movement of the electrodes, and could last a timeline, according to the researchers.<\/p>\n<p>The team is also now working to miniaturize the device further and they plan to use <a href=\"https:\/\/en.wikipedia.org\/wiki\/Beam_steering\" >beam-steering<\/a> technology to focus the ultrasonic signals on individual motes. The team is also building little backpacks for rats to hold the ultrasound transceiver that will record data from implanted motes. And the researchers are working to expand the motes\u2019 ability to detect non-electrical signals, such as oxygen or hormone levels.<\/p>\n<p>The researchers estimate that they could eventually shrink the sensors down to a cube 50 micrometers on a side. At that size, the motes could monitor a few specific nerve axons and continually record their electrical activity.<\/p>\n<p>The researchers conceived of the idea of neural dust about five years ago, but initial attempts to power an implantable device and read out the data using radio waves were disappointing. Radio attenuates very quickly with distance in tissue, so communicating with devices deep in the body would be difficult without using potentially damaging high-intensity radiation. In 2013, the researchers published an open-access <em>arXiv<\/em> <a href=\"http:\/\/arxiv.org\/abs\/1307.2196\" >paper<\/a> that described how a neural-dust system with ultrasonic signals might work.<\/p>\n<p>The ongoing research is supported by the U.S. Defense Advanced Research Projects Agency as part of DARPA\u2019s\u00a0<a href=\"http:\/\/www.darpa.mil\/program\/electrical-prescriptions\">Electrical Prescriptions (ElectRx)<\/a>\u00a0program, which is focused in part on developing interface technologies that are suitable for chronic use for biosensing and neuromodulation of specific peripheral nerves.<\/p>\n<p><iframe frameborder=\"0\" height=\"360\" src=\"https:\/\/www.youtube.com\/embed\/oO0zy30n_jQ?rel=0\" width=\"640\"><\/iframe><br \/>\n<em>UC Berkeley | \u201cNeural dust\u201d sensor<\/em><\/p>\n<hr \/>\n<p><strong>Abstract of <em>Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust<\/em><\/strong><\/p>\n<p>The emerging field of bioelectronic medicine seeks methods for deciphering and modulating electrophysiological activity in the body to attain therapeutic effects at target organs. Current approaches to interfacing with peripheral nerves and muscles rely heavily on wires, creating problems for chronic use, while emerging wireless approaches lack the size scalability necessary to interrogate small-diameter nerves. Furthermore, conventional electrode-based technologies lack the capability to record from nerves with high spatial resolution or to record independently from many discrete sites within a nerve bundle. Here, we demonstrate neural dust, a wireless\u00a0and scalable ultrasonic backscatter system for\u00a0powering and communicating with implanted bioelectronics. We show that ultrasound is effective\u00a0at\u00a0delivering power to mm-scale devices in tissue; likewise, passive, battery-less communication using\u00a0backscatter enables high-fidelity transmission of electromyogram (EMG) and electroneurogram (ENG) signals from anesthetized rats. These results highlight the potential for an ultrasound-based neural interface system for advancing future bioelectronics-based therapies.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>University of California, Berkeley engineers have designed and built millimeter-scale device wireless, batteryless &ldquo;neural dust&rdquo; sensors and implanted them in muscles and peripheral nerves of rats to make in&nbsp;vivo electrophysiological recordings. The new technology opens the door to &ldquo;electroceuticals&rdquo; &mdash; bioelectronic methods to monitor and record wireless electromyogram (EMG) signals from muscle membranes and electroneurogram [&#8230;]<\/p>\n","protected":false},"author":13,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[49,48,43],"tags":[],"class_list":["post-9645","post","type-post","status-publish","format-standard","hentry","category-cognitive-scienceneuroscience","category-electronics","category-news"],"_links":{"self":[{"href":"https:\/\/hoo.central12.com\/fugic\/wp-json\/wp\/v2\/posts\/9645"}],"collection":[{"href":"https:\/\/hoo.central12.com\/fugic\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/hoo.central12.com\/fugic\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/hoo.central12.com\/fugic\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/hoo.central12.com\/fugic\/wp-json\/wp\/v2\/comments?post=9645"}],"version-history":[{"count":3,"href":"https:\/\/hoo.central12.com\/fugic\/wp-json\/wp\/v2\/posts\/9645\/revisions"}],"predecessor-version":[{"id":9739,"href":"https:\/\/hoo.central12.com\/fugic\/wp-json\/wp\/v2\/posts\/9645\/revisions\/9739"}],"wp:attachment":[{"href":"https:\/\/hoo.central12.com\/fugic\/wp-json\/wp\/v2\/media?parent=9645"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/hoo.central12.com\/fugic\/wp-json\/wp\/v2\/categories?post=9645"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/hoo.central12.com\/fugic\/wp-json\/wp\/v2\/tags?post=9645"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}